SKU: LRU26Z

Simpson LRU26Z Light Rafter U Hanger - Slopeable 2x6 - Zmax Finish

Simpson LRU26Z Light Rafter U Hanger - Slopeable 2x6 - Zmax Finish!

Skip to product information
1 of 2

Continue Browsing

LRUZ Rafter Hangers

$5.38
 
Request Bulk Pricing
Request Bulk Pricing
Ships today, order in the next 3 hours 40 minutes
Fill out the form below or give our sales consultants a call at 866-421-4854.

Specifications

Finish: ZMAX
Fasteners required: SEE PRODUCT GUIDE DOCUMENT
For Treated Lumber: Yes
Height: 5-1/4"
Manufacturer name: Simpson Strong-Tie
Width: 1-9/16"
Description

Simpson Strong-Tie LRU light rafter U hangers are an economic alternative for applications requiring a sloped hanger for rafter-to-ridge connections. Used with solid-sawn rafters, the LRUZ’s unique design enables the hanger to be installed either before or after the rafter is in place. The field-adjustable seat helps improve job efficiency by eliminating mismatched angles in the field and lead times associated with special orders. The LRUZ offers comparable or better load capacity to other rafter hangers at a reduced cost while using fewer fasteners.The Strong-Tie LRU26Z reinforcing angle features a G185 ZMAX galvanized finish for added corrosion resistance and requires the use of hot-dip galvanized fasteners which meet the specifications of ASTM A153.


Features:
  • The open design and ability to field-adjust the slope makes the LRUZ ideal for both retrofit or new applications
  • Accommodates roof pitches from 0:12 to 14:12
  • Slopes up or down to 45° (12:12). For slopes greater than 45° up to 49° (14:12), allowable loads are 0.85 of table loads
  • For added versatility the fasteners are placed higher on the hanger allowing the bottom of the rafter to hang below the ridge beam (see "Max. C1" dimension in table)
  • Can be installed using nails or Strong-Drive® SD Connector screws

Installation:
  • Use all specified fasteners.
  • Joist fasteners must be installed at an angle through the rafter or joist into the header to achieve the table loads.

NOTE: The correct fasteners installed in the correct position must be used to achieve published load values


California Residents: WARNING

View full details

Continue Browsing

LRUZ Rafter Hangers

× WARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects and other reproductive harm. For more information visit: www.P65Warnings.ca.gov.

Customer Reviews

Based on 3 reviews
67%
(2)
0%
(0)
0%
(0)
0%
(0)
33%
(1)
R
Rachelle

Never received

Rachelle,
Thank you for your review! We are so sorry to hear that you have not received your order. A customer service representative will be reaching out to you directly to look into this further and provide resolution. Thank you for bringing this to our attention!

R
ROGER JONES
Best rafter clip

Really makes it easy to conventional frame a roof and meet hurricane ratings for engineering. Frame up as normal and add the rafter clips after.

M
Mark Canneto
Worked great for our project

These saved the day in our wall opening LVL project. My contractor said they worked perfectly. Thanks for making such a greet product.